Filter Results By:

Products

Applications

Manufacturers

Test Leads

Cable hook-up between a test node and test instrument.

See Also: Flying Leads, Multimeters


Showing results: 466 - 480 of 521 items found.

  • 1500A True RMS AC/DC Clamp Meter + NCV

    Extech MA1500 - Extech Instruments Corporation

    The MA1500 is a 1500A True RMS AC/DC Clamp Meter. 2.0 in. (52mm) jaw size for conductors up to 500MCM with True RMS for accurate readings of non-sinusoidal waveforms. Additional features include: Relative Mode for Capacitance Zero and Offset Adjustment, Data Hold, Peak Hold, MIN/MAX, Auto Power Off, and Inrush function to capture transients during motor startup. Complete with test leads, Type K bead wire temperature probe, 9V battery and carrying case.

  • 600A True RMS AC Clamp Meter + NCV

    Extech MA620 - Extech Instruments Corporation

    MA620 is a True RMS, autoranging AC clamp meters offer plant maintenance techs, electrical troubleshooters, and DIYers a test instrument that delivers a combination of high performance and exceptional value. In addition to a host of advanced multimeter and current measurement capabilities, it also has a built-in, non-contact (NCV) voltage detector. You can select auto- or manual-ranging modes, measurement functions cover all types of troubleshooting over and above noninvasive current probe measurements: voltage, resistance, capacitance, frequency, duty cycle, diode and continuity tests. Even measure temperature with the supplied Type K bead wire probe. Complete with test leads, general purpose Type K bead wire temperature probe, 9V battery and carrying case.

  • 12V 0-500 Amp Carbon Pile Battery Load Tester and 12/24V Electrical Systems Tester

    6042 - Associated Equipment Corp.

    • Test batteries up to 1000 CCA• Interprets data from the charging/starting system on easy-to-read LCD displays• Shows positive and negative amps for easy diagnosis of current leakage problems• 0-500 Amp variable carbon pile load tester• Unique curved carbon discs ensure maximum contact, fewer hot spots, smoother operation and longer life• Heavy-duty single extruded leads for testing up to 15 feet apart• Test electrical systems on 12/24 Volt systems• Test all battery types• Ideal for testing remotely mounted batteries accurately• INCLUDES: Model 6043 1000 Amp AC/DC Inductive Amp Clamp for checking starter draw or parasitic drain test, also can be used with conventional multi-meters; heavy duty, two wheel tilt-back cart with 8” wheels and 2 trays.• Made in USA of US and Global Components

  • 12V Automatic Battery and 12/24V Electrical System Analyzer

    6044 - Associated Equipment Corp.

    • Easy-to-read LED voltmeter and ammeter• 500 amp safety clamps with “Flexi-Spring” and patented side terminal adapters• Separate 6 ft. high impedance test leads with alligator clips for tight spots• Cart / Printer can be purchased separately – Cart Model 6038C, Printer Model 6041• Automated testing of Batteries, Alternators, & Starters• Max/Min of Current and Voltage• Microprocessor based control board protected from reverse connections• Testing of 12V and 24V electrical systems• Test all types of batteries • Ideal for testing remotely mounted batteries accurately• Automated 500A variable load tester• INCLUDES: Model 6043 1000 Amp AC/DC Inductive Amp Clamp for checking starter draw or parasitic drain test, also can be used with conventional multi-meters• Made in USA of US and Global Components

  • Underground Cable Fault Locator

    KM-CFPL-620 /620B - Kusam Electrical Industries Limited

    “KUSAM-MECO” underground Cable Fault Pre-locator is an automatic Cable Fault Locator which adopts ARM, FPGA & Dot Matrix Color LCD display Technology. This tester combines both pulse reflecting technology (TDR) & (intelligent Bridge testing (Bridge) (Model-KM-CFPL-620B) for measuring the exact fault location such as broken line, cross faults, earthing, (poor insulation & poor contact of the lead covered cables as well as plastic cables. (Model-KM-CFPL-620B)).It is a microprocessor based fault locator with a user friendly menu. It is easy to operate. It tests almost all telecom & signal cables. It has an English menu which is easy to understand & use. With Megameter & Ohmmeter it enables to test insulation resistance & loop resistance. It has USB Port for uploading test data to computer

  • 11 Function Heavy Duty True RMS Industrial MultiMeter

    Extech EX520 - Extech Instruments Corporation

    Designed to withstand harsh environments and usage, the meter's rugged, double-molded housing is IP67-rated (waterproof and dustproof) and drop-tested to 6 ft. The large, illuminated LCD displays 4-digit readout (to 6,000 counts). The EX520 offers various must-have measurements. The meter features 0.09 percent accuracy and a CAT IV 600-volt safety rating, protecting users even on outdoor wiring. Product includes a 3 year warranty, double molded test leads, 9V battery, magnetic hanging strap, temperature probe and carrying case.

  • Loudspeaker Cable Testers

    EMO E450 - EMO Systems Canford Audio PLC

    The EMO E450 cable tester will test for continuity, cross connection, and open circuit in cables fitted with NL8FC 8-pole and NL4FC 4-pole Speakon connectors, 3-pin XLR connectors, and 2 or 3 pole A-gauge jacks. EP retrofit kits are available to allow cables fitted with EP 4, 5, 6, or 8 pin connectors to be tested. The EP connectors fit in two pre-punched holes on the rear of the tester accessed by removing the blanking panel. The kit's flying leads plug directly into connectors mounted on the tester's PCB.

  • 10KV High Voltage Digital Insulation Resistance Tester

    KM 6213AIN - Kusam Electrical Industries Limited

    • The KM 6213A IN is the KUSAM-MECO premium model of High Voltage Digital Insulation Resistance Testers.• The KM 6213A IN has new added features with a low consumption High Performance processor.• It displays results much faster and has more advanced features.• The KM 6213A IN has Automatic Polarization Index and Dielectric Absorption Ratio Calculations.• Results are displayed on the new High Contrast LCD. It’s mounting angle makes it more readable for all users, in different working conditions.• The user’s manual reflects the new features and added benefits of this instrument.• It has Auto-Off, Auto-Stop, EnerSave™ and is a non destructive tester.• Once you start the tester, it waits for your selection. You can go up and down in voltage to select the voltage at which you want to test the insulation. Once you have selected that voltage, you need to connect the test leads to the Insulation Tester to measure. Then it measures voltage to ensure there is no voltage present on the equipment under test. If there is a voltage present, it will warn you to disconnect the circuit before proceeding. If it’s free of any voltage, then you can proceed with the testing. This ensures that no damage is done to the Insulation Tester KM 6213AIN.• One of the new innovation on this tester is also the way the new unique calibration process works. It’s fully digital, has no moving parts and does not require expensive and complicated jigs or computers systems to be calibrated. It’s cheaper to maintain than any other Digital HV Insulation tester on the market today. The KM 6213AIN is supplied standard with our Premium test Leads Kit, the AL-50.

  • Industrial Clamp Meters

    Greenlee Tools

    *Measures AC+DC current*AC and AC+DC voltage measurements with digital low pass filter for accurate readings on variable frequency drives*Also measures DC voltage, resistance, capacitance and frequency*Tests continuity and diodes*Flashlight inside clamp jaw for easier work in dark locations*Backlight & relative mode for added versatility*Peak-RMS measures motor inrush current*AmpTip™ increases accuracy on small wires and low current*Two voltage detection modes - non-contact or using a single test lead*Data hold*Recording of Maximum, Minimum, and Average readings*Crest (peak hold) feature captures current or voltage peaks as short as 5 milliseconds

  • 11 Function True RMS Professional MultiMeter

    Extech EX430A - Extech Instruments Corporation

    The Extech EX430A True RMS Autoranging Multimeter (with K Type, Capacitance, Frequency, and Duty Cycle) is a professional grade True RMS multimeter capable of performing a wide range of measurements. Functions include AC and DC voltage to 600V, AC and DC current to 10A, resistance to 40MOhm, continuity and diode test. Also includes a Type K thermometer function for contact or air temperature measurements from -4 to 1832°F (-20 to 750°C). Advanced functions include Capacitance, Frequency and Duty Cycle. The meter comes complete with test leads, Type K temperature probe, 9V battery, protective holster, adjustable tilt stand and Velcro hanging strap.

  • Contact Resistance Test Sets

    Megger Group Ltd.

    When a high current passes through a pair of mechanically independent metallic contacts, the resistance must be as low as possible. An increase in resistance can lead to additional degradation, as I2R losses will cause local heating of the contact surfaces. Our range of micro-ohmmeters measure both steady state and dynamic low resistance values. With test currents up to 600A available, logging and trending are also available on some models. We ensure that our Contact Resistance tests sets are portable, making them suitable for field measurements. Our contact resistance testers’ portability makes them ideal for a vast range of resistance testing across the entire LV, MV HV and EHV spectrum.

  • 1 A DIGITAL MILIOHMMETER

    MO-2Ke - MEGABRAS srl

    The MO-2Ke digital low resistance ohmmeter is a portable, microprocessor-controlled instrument used to accurately measure resistances of contacts, switches, transformer and motor windings, etc., using test currents from 1 mA up to 1 A.It uses the Kelvin-type (4-terminals) measurement principle, thus eliminating errors caused by lead and contact resistances.Resistance readings are shown in the alphanumeric display with up to a 4 digit-resolution. It allows to measure resistances of up to 2 kO, with resolution of 0.01 mO.Measurements accuracy is guaranteed by the state-of-the-art system for signal-amplification, offset-free and with long-term stability.

  • 400A True RMS AC/DC Watt Clamp-on - Measures Watts, Current, and Voltage

    Extech 380940 - Extech Instruments Corporation

    The compact Extech 380940 is a 400 Amp mini True RMS AC/DC power clamp meter with a small diameter jaw designed to reach in small areas while providing power calculations up to 240kW. With the added convenience of instant watt readings, a feature normally reserved for full-size meters, this mini power clamp is useful for essential troubleshooting tasks in plant maintenance, electrical, HVAC, and telecom work, as well as residential electrical repairs, energy audits, fleet maintenance, marine, and motorcycle repair. Complete with test leads, 2 AA batteries, and carrying case.

  • Digital LOOP/PSC/EARTH Tester

    1824 LP - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. (you do not need to add all the bonding points and connection paths)● Displays voltage supply at the transformer(Line to Neutral), without loading the transformer.● Single one smart push button operation; ON, Scroll through results and menus.● Checks wiring integrity (LEDs).● Auto-off / Auto-ranging (software range).● Color-coded test leads.● Combined prospective short circuit current, loop, and earth tester.● Loop test for L-E and PSC between L-N.● Voltage test L-N.● Display can be customized for large orders.

  • Three-Phase Transformer Winding Resistance Meters

    TWA Standard Series - IBEKO Power AB

    When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.

Get Help